Product information
[

2013 Portable AC Ammeters and Voltmeters

]
If you are interested in the product, then,Can ProductName: 2013 Portable AC Ammeters and Voltmeters
ProductModel: yokogawa 2013
ProductManufacturer: other brand
ProductSimpleIntroduce: 2013 Portable AC Ammeters and Voltmeters,yokogawa 2013 Ammeters and Voltmeters,201301,201302,201303,201304,201305,201306,201307,201308,201309,201310,201311,201312,201313,201314,201320,201322,201315,20

2013 Portable AC Ammeters and Voltmetersdetail

2013 Portable AC Ammeters and Voltmeters
・Moving iron type
・Cup shield mechanism decreases the effect of external magnetic field
・Temperature compensation circuit is provided
・Temperature compensation circuit is provided

Models 2013 and 2014 are moving iron type instruments using a taut-band suspensionsystem.

The suspension system provides excellent reproducibility without friction, andgood resistance to shock impact.

A cap shield mechanism serving to reduce external magneticfields, a superior temperature compensation
circuit, and other components ensure stable performance.

Features

Taut-band suspension system eliminates friction
and provides good resistance to shock impact.
Stable performance ensures that changes overtime are negligible.
Magnetic circuit reduces the effects of externalmagnetic fields.
 Superior temperature compensation circuitr educes external temperature effects.

Specifications

Operating principle : Moving iron type
Class : JIS C 1102, equivalent to Class 0.5
Operating position : Horizontal
Scale length : Approximately 135 mm (deflection angle: 85°)
Rated Frequency : 50/60 Hz
Scale divisions : Check the symbols below against the instrument list.
A: 100 divisions B: 150 divisions C: 100/150 divisions
D: 100/125 divisions E: 120/150 divisions

Operating temperature and humidity ranges : 0 to 40°C, 25 to 80%RH
Storage temperature and humidity ranges : -10 to 50°C, 25 to 80%RH
Insulation test : Between electrical circuit and the case DC 500 V/More than 10 MΩ
Voltage test : Between electrical circuit and the case AC 3000 V for 5 seconds
External dimensions and weight :
2013 Approximately 197 × 181 × 92 mm, approximately 1.7 kg
2014 Approximately 260 × 180 × 120 mm, approximately 4.2 kg
Standard accessories : Instruction Manual (1)
Current transformer 2244 (2013 22)
Optional accessories (sold separately) : 2291 01 Carrying case for 2013 (page 10)
2292 01 Carrying case for 2014 (page 10)

 

 

Model

Maximum scale value

Approximate internal resistance
and consumed power

AC Ammeters

2013 01

20/100 mA

0.3/0.2 AV

2013 02

50/250 mA

0.5/0.5 VA

2013 03

100/500 mA

0.5/0.5 VA

2013 04

0.2/1 A

0.4/0.4 VA

2013 05

0.5/2.5 A

0.5/0.5 VA

2013 06

1/5 A

0.6/0.6 VA

2013 07

2/10 A

0.7/0.7 VA

2013 08

5/25 A

1/1 VA

2013 09

10/50 A

1.2/1.8 VA

2013 10

20/50/100/200 mA

0.4/0.3/0.2/0.3 VA

2013 11

0.1/0.2/0.5/1 A

 0.2/0.3/0.4/0.5 VA

2013 12

0.5/1/2/5 A

0.7/0.6/0.5/0.3 VA

2013 13

2/5/10/20 A

0.5/0.3/0.6/0.9 VA

2013 14

10/20/50/100 A

0.6/0.9/1.7/2.4 VA

2013 20

5A

 0.22 VA

2013 22

500A

 Used in combination with current transformer 2244 (accessory)

AC Voltmeters

2013 15

15/30 V

3.8 VA

2013 16

30/75 V

3.8 VA

2013 17

75/150 V

3.8 VA

2013 18

150/300V

3.8 VA

2013 19

300/750 V

3.8 VA

2013 21 

150V

3.8 VA

2013 28

150/300/600V

3/3/6 VA

AC400HZ Ammeters

2013 23

0.5/1/2/5 A

0.7/0.6/0.5/0.3 VA

2013 24

2/5/10/20 A

0.5/0.3/0.6/0.9VA

2013 25

10/20/50/100 A

0.6/0.9/1.7/2.4 VA

AC400HZ Voltmeters

2013 26

75/150V

3.75VA

2013 27

150/300V

3.75VA

 

Notes
1. For ranges higher than 100 A, externally connect current transformer 2241 or 2242 (page 9) to the 5 A terminal on 2013 20 (5 A instrument) or 2013,or the 7.5 A terminal on 2014.


2. For ranges higher than 750 V, use to 2013 21 (150V instrument), or externally connect voltage transformer 2261 or 2262 (page 9) to the 150 V
terminal on 2013 or 2014.

3. The scales on 2013 20 (5 A instrument) and 201321 (150 V instrument) are dual scale (100 and150) with both scales printed. These standard scales are easy to use through a simple conversion process with CTs and VTs of any rating. DC scales (single scale or dual scale) are also available by special order.

Leave a message for product
Title
Contact
Tel
Content
Verify Code
Click to change
Note:1. Shortcut key for send message :Alt+s or Ctrl+Enter!
2. If necessary, please leave your detail contact!

Copyright © 2005 JAM POK (H.K.) TECHNOLOGY LIMITED. All rights reserved
Copyright© 2003-2025  JAM POK (H.K.) TECHNOLOGY LIMITEDCopyright &nbs
No. 75 Unit B2, 7/F, Eastern Sea Industrial Building No. 48-56Tai Lin Pai Road,Kwai Chung, N.T.