UT351 Digital Indicating Controller
]
If you are interested in the product, then,Can
ProductName:
UT351 Digital Indicating Controller
ProductModel:
UT351-00,UT351-01,UT351-02,UT351-20,UT351-20,UT351
ProductManufacturer:
other brand
ProductSimpleIntroduce:
UT351 Digital Indicating Controller,UT351-00,UT351-01,UT351-02,UT351-20,UT351-20,UT351,yokogawa UT351 Digital Indicating Controller.
UT351 Digital Indicating Controllerdetail
UT351 Digital Indicating Controller
The UT351 Digital Indicating Controller (1/4 DIN size) is a compact, versatile, general-purpose instrument that comes with Active Color PV Display function, which changes LED color of large display between Green-color and Red-color automatically based on a PV deviation or Alarm status. UT351 also provides an easy-to-see large display for readings, along with an AUTO/MAN switching key, offering excellent monitoring and operability. Control functions include optional heating/cooling control, as well as autotuning, PID control with the "SUPER" overshoot suppress function and additionally new "SUPER2" hunting suppress function. Retransmission output and sensor power supply (15 V DC) come as standard.
- Active Color PV display features:
- Alarm Status: Active color display changes from green (normal) to red (alarm) automatically.
- Deviation Status: Color changes based on a PV deviation from SP.
- User-defined Color: Choose between green or red display for constant readings.
- Sharp and large 4-digit display
Dramatic increase in visibility using large LED display with 11 x 20 mm digits
- Standard retransmission output (also usable as 15 V DC loop power supply terminals).
- Optional heating/cooling control
- Optional heater disconnection alarm
- Optional 24 V DC Loop Power Supply (24 V LPS) for 2-wire transmitters.
- Support for Light Loader - LL100 PC-based Parameter Setting Tool
Easy parameter setting on a PC screen, enabling data to be transmitted through the front panel using an optical communication adapter.
- Easy to understand hardcopy format and handy CD-ROM user's manuals.
- New communication method
MODBUS, PC-Link & Ladder protocols and coordinated operation are supported.
Model | UT351 |
PV/SP Data display | 4 digits Active Color / 4 digits |
PV Input | 1 universal input (TCs, RTDs, mV, V) |
Indication accuracy | 0.1% ±1digit |
Auxiliary Analog Input | Not Available |
Control scan period | 250ms |
Control loops | 1 |
Control modes | MAN/AUTO |
Number of Setpoint(SP) | 4 |
Control Algorithm | ON/OFF, Time-proportional PID, Continuous PID, Heating & Cooling |
SUPER, Auto tuning | SUPER, SUPER2, AT |
Control Outputs(MV) | Select from Relay, Voltage Pulse or 4 to 20mA |
Auxiliary Analog Output ( 1) (4 to 20mA) | 1 point except for Heating/Cooling control ( Cannot use with LPS15V ) |
Loop Power Supply (LPS) | 2 points, 15V and 24V(option) |
Digital Inputs | 2 |
Digital Outputs | 3 |
Industrial Ethernet | Available |
RS485 Communication Protocols | Four-wire, Protocol is MODBUS, PC-link, Ladder or Coordinated Operation. |
Approvals | General = UL, CE, CSA Front Protection = IP55 |
Other specifications | Size=96(W)*96(H)*100(D)mm, Power supply =90 to 264V AC, Power consumption=max. 20VA |
Ambient T, Limits RH | 0 to 50℃, 20 to 90%RH |
Model | Suffix Code | Description |
UT351 | | | Digital indicating controller, with Active color PV display |
Type | -0 | | Standard type |
-2 | | Heating/cooling type |
-3 | | Standard type with 24V DC loop power supply |
Options | 0 | None |
1 | Communication functions, heater burnout alarm (2 points) Note |
2 | Heater burnout alarm (2 points) Note |
A | Ethernet communication* |
Note: Sensor of heater burnout alarm is CTL-6-Sor CTL-12-S36-8(URD Co.,Ltd., Japan)To be purchased separately