UT150 Temperature Controller
]
If you are interested in the product, then,Can
ProductName:
UT150 Temperature Controller
ProductModel:
UT150-RN UT150-AN UT150-VN UT150-RN/AL UT150-VN/AL
ProductManufacturer:
other brand
ProductSimpleIntroduce:
UT150 Temperature Controller ,yokogawa UT150,UT150-RN UT150-AN UT150-VN UT150-RN/AL UT150-VN/AL。
UT150 Temperature Controller detail
UT150 Temperature Controller
The UT150 Temperature Controller (1/16 DIN size) is a compact, versatile, general-purpose temperature controller. The UT150 has a dynamic auto tune and the "SUPER" overshoot suppress function as standard function. The heating/cooling control, retransmission output, timer function and communication function are available as optional features.
- Small, space-saving 1/16DIN package, 48 (W) x 48 (H) x 100 (D) (mm)
- Large 4-digit LED display
- IP65 splash-proof and dust-proof designed front panel
- Universal input for Thermocouple, RTD and DC mV/V signals
- Universal input for Thermocouple, RTD and DC mV/V signals
- Optional heating/cooling control capability
- Optional retransmission output of measured value (PV)
- Optional timer function
- Optional heater burnout alarm and two alarm output relays
- Standard universal power supply (100 V to 240 V AC) and optional 24 V AC/DC power supply
- Optional RS485 communication function, MODBUS, PC-Link & Ladder protocols are supported
PV/SP Data display | 4 digits / 4 digits |
PV Input | 1 universal input (TCs, RTDs, mV, V) |
Indication accuracy | ±2°C 1digit for TC ±1°C 1digit for RTD ±0.3% 1digit for mV/V input |
Control scan period | 500ms |
Control loops and mode | 1 loop, AUTO mode only |
Number of Setpoint (SP) | 2 |
Number of Program patterns/segments | NA |
Control Algorithm | ON/OFF, Time-proportional PID, Continuous PID, Heating & Cooling |
SUPER, Auto tuning | SUPER, Dynamic AT |
Control Outputs | Select from Relay, Voltage Pulse or 4 to 20mA |
PV Retransmission Output | 1 point (4 to 20mA) |
Timer function | Two timers (0 to 99min.59sec) |
Program time span | NA |
Digital Inputs | 2 (sp1/sp2, RUN/STOP, Timer function) |
Digital Outputs | 2 (Alarm or Timer outputs) |
RS485 Communication Protocols | Two-wire, MODBUS, PC-link, Ladder |
Approvals | General = UL, CE, CSA Front Protection= IP65 |
Other specifications | Size=48*48*100mm, Power supply = 24VAC/DC or 90 to 264V AC, Power consumption=8VA |
Ambient T, Limits RH | 0 to 50℃, 20 to 90% |
Model | Suffix | Code Description |
UT150 | □□ | | Temperature controller |
Output signal (for heating) Note 1 | - R | | | Relay contact output(for time-proportional PID or on/off control) |
- V | | | Voltage pulse output (for time-proportional PID) |
- A | | | 4 to 20 mA output (for continuous PID) Note1 |
Output signal for cooling | | - N | | No cooling output (Standard type) |
| - R | | Relay contact output (for time-proportional PID control) |
| - V | | Voltage pulse output (for time-proportional PID) |
| - A | | 4 to 20 mA output (for continuous PID) |
Options | /AL | Alarm outputs (2 points) Note 2 |
/HBA | Heater burnout alarm and 2 other alarm outputs (includes the functions of /AL) Notes 1, 2, 3, 6, 7 |
/EX | Switchover between SP1 and SP2, and starting of timer by external contacts Notes 4, 6 |
/RET | 4 to 20 mA retransmission output of measured value (PV) Notes 3, 5 |
/RS | Communication function Notes 4, 6 |
/V24 | Power Supply 24VDC/24VAC |
Notes
Note 1:"/HBA" can not be specified when selecting."-A:4 to 20mAoutput".
Note 2:"/AL" can not be specified when "/HBA" is specified.
Note 3:"/HBA" and "/RET" cannot be specified at the same timewhen selecting standard type.
Note 4:"/EX" and "/RS" cannot be specified at the same time when selecting standard type.
Note 5:"/RET" cannot be specified when selecting heating/coolingtype.
Note 6:"/HBA","/EX" and "/RS" cannot be specified at the same timewhen selecting heating / cooling type.
Note 7:Sensor of heater burnout alarm is CTL-6-S or CTL-12-S36-8(URD Co., Ltd., Japan) To be purchased separately